Guide :Home Security : Sl 3000 Ul Sliding Gate Operator

Sliding gate will not close

Our sliding gate, which is operated by the Elite Sl 3000-UL system, keeps returning to open position when we tried to close it with the remote. It will close about halfway in its track, but then slides back open. We can close the gate by pushing it manually, but when in closed position, you can actually push it open. The gate also have a photoeye sensor. Any suggestions to fix the problem will be greatly appreciated! Alvin Long Beach, CA

Research, Knowledge and Information :


My Gate Won't Close -- How Do I Fix My Broken Driveway Gate?


My Gate Won't Close -- How Do I Fix My Broken Driveway Gate? ... If your gate is a slide gate, look for broken wheel bearings, damaged track, or damaged chain.
Read More At : automaticgateinfo.com...

Common Problems with Automatic Gates


What are the common problems with automatic gates ... Sliding Gate Stops when not ... This is easily checked by crouching down and having a close look at where ...
Read More At : www.grantsautomation.com.au...

5 Problems with Automatic Gates and How to Fix Them


... automatic gates can go ... Automatic Gate Tracks. Sliding gates are the most common ... your annual service which is why your gate will not open / close ...
Read More At : alphagateautomation.com.au...

Electronic Drive Gate Not Opening Or Closing - YouTube


Mar 05, 2013 · Kung Fu Maintenance demonstrates how to reset an electronic drive gate that is not opening or closing. Won't open or close. Buy The Kung Fu Maintenance E ...

Most common problems with automated gate openers | Gate openers


If the power is off this mode will allow the gate to open and close. ... Review: ALEKO AR1500 Sliding Gate Opener; LiftMaster gate openers – top 5 models (reviews)
Read More At : www.gateopenersreview.com...

TROUBLESHOOTING PATRIOT RSL SLIDE GATE OPERATOR


TROUBLESHOOTING PATRIOT RSL SLIDE GATE OPERATOR 4 5. My gate will not automatically close: NOTE: If DS1 switch 1 is on and switch 2 is off then the gate should ...
Read More At : usautomaticgateopeners.com...

Troubleshooting Sliding Electric Gate Motors | DoItYourself.com


Troubleshooting Sliding Electric Gate Motors Troubleshooting Sliding ... that sends a radio signal to a receiver box that is usually mounted close to the gate.
Read More At : www.doityourself.com...

Gate operator - Wikipedia


A gate operator is a mechanical device used to open and close a gate, ... Automatic and Electric Gate operators are designed for both swinging and sliding gates.
Read More At : en.wikipedia.org...

Sliding gate - YouTube


Jul 28, 2017 · Sliding gate Contact: Emagic technologies Ph:8589088407 ... This feature is not available right now. Please try again later.

Suggested Questions And Answer :


Sliding gate will not close


I'm finding every answer except the one I'm looking for.. My sliding gate won't open everytime. I have to push the remote transmitter several times. Can you please tell me why? And how to resolve the problem? Thank You
Read More At : Sl 3000 Ul Sliding Gate Operator...

My elite operator will only close part way, seems to only happen cold nights 52 degrees-F works well in the day time no matter the temperature, limit switches checks out ok, I disconnected the loop detector and the operator still will not close, disconnected the gate and run the operator still stalls to close without the gate load. Have not problems what so ever when opening.


You will have to increase your force (sensitivity) settings on the p.c. board. Without knowing what type of board you have I can only guess. There should be a pod you can rotate with a screwdriver to increase the force. If it has an LCD readout with menus search the menus for force or obstruction, then increase it. freddy51
Read More At : Sl 3000 Ul Sliding Gate Operator...

Hi,, i have a SL3000UL slide gate opener that stops half way.


Check for loop detection or failure on the loop detector (s). Make sure if using more than one detector, your frequencies are not identical. Must be set differently. If loops are suspect, you will have to "meg" the loop wires to check for earth ground. (Bad loops will cause irratic gate function). You need a megometer to do this. It puts out 500 volts through loop wires. You can also check for severed loop wire via continuity setting of a volt meter. Check reverse sensitivity on operator circuit board. If too sensitive, the slightest resistance on the roller system will cause stoppage or retraction. Wheel drag. If wheel axle bolts or bearings are worn, gate closure or opening can be affected. Pull emergency release or remove chain from gear sprocket and push/pull gate panel (free-wheeling). If hard to push/pull, wheels need replacement. In a nutshell, too many factors involved to give definitive answer via Internet.
Read More At : Sl 3000 Ul Sliding Gate Operator...

My Elite SL3000 sliding gate is not responding to any of my remotes(open/close) but I hear the receiver in the operator clicking when I press the remote. My son mentioned that when he passed through the open gate the infared sensor clicked and caused the gate to start closing. Odd! later I found the gate had opened by itself and now it is not reponding to my remotes. we did have a big rain shower earlier. Could the infared sensor be fogged up and giving it false info thinking something is in the way and therefore not allowing the remotes to respond?


Hi, Thanks for posting your Question.When it comes to automatic usage of equipment or gadget that work with remotes sensors..It always malfunctions when water enters into it's electrical area..Issues like this are have to be checked by an experienced Elite SL3000 sliding gate repairer..Water has enter either the coil area or the magnet that control the opening and closing function of the Gate..It's not from the remote. That is if the battery of the remote still functions properly..It needs to be serviced to clean the water inside and after cleaning it up, it will be ok..Please make sure someone who has the experience should handle it. ThanksGood luck ..
Read More At : Sl 3000 Ul Sliding Gate Operator...

I have al Elite 3000 sl sliding gate opener that is not shutting. When I disconnect the electric power, it closes the gate sometimes half way and it stops, sometimes it closes the gate after one hour


Might also be a issue with the "safety" loop(s), loop detector, loop detector scensativaty frequency, photo cell damaged, photo cell out of aline, faulty or stuck safety edge, faulty receiver, stuck remote control, hold open switch and or timer is set to function or is faulty. Some to none of these may and may not be helpful do to some features listed may not apply to your set up.
Read More At : Sl 3000 Ul Sliding Gate Operator...

I have an Elite gate operator. I had several friends over for a visit and they all arrived at the same time. Three cars lined up at the entrance gate and the first car punched in the gate code. The gate opened allowing the first car, then the second car to safely enter the property. As the third car passed through the gate following the second car, the gate began closing striking the side of the third car causing some damage. Please advise what you think the problem might be. We have recently repaved the driveway with approximately two inches of new asphalt, would this interfere with the magnetic loop sensor not being able to pick up the cars coming in as they passed over the loop????


You need to put safety beams in if you have your auto close function enabled on your gate motor. If you had the safety beams installed your gate wouldn't have closed on the 3rd car. The loop you have installed is only really for cars leaving your premises without you having to open the gate or them entering a code to open from the inside
Read More At : Sl 3000 Ul Sliding Gate Operator...

The gate stop at the midle of the entrance .overload light turn on then no movement at all no open no close nothing .in an hour the gate close itself then cant be open when open manually its close by its self and keep doing this . everytime the overload light turn on


Get a can of aerosol grease, do not use WD 40. Use the grease to lube all of the moving parts and then run it. Repeat the lubing as necessary. J.
Read More At : Sl 3000 Ul Sliding Gate Operator...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || home-security-101.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0243 seconds